for various use.
Also not standardized but trade usual types are included in the program!
Suitable for government testing, with works certificate and government tested with verification certificate.
Developed for the following measures:
for the determination of the dropping point of lubricating greases and bitumen |
||
|
||||||
Catalogue no. |
Type |
Measuring range |
Form |
Immersion |
||
M230000 |
0+70:0,5°C |
enclosed scale |
57 mm |
|||
M230002 |
flash point Abel Pensky |
+35+100:1°C |
enclosed scale |
75 mm |
||
M230006 |
flash point Abel Pensky |
-30+30:0,5°C |
enclosed scale |
57 mm |
||
M230008 |
flash point Abel Pensky |
-30+30:1°C |
enclosed scale |
75 mm |
||
M230042 |
flash point Pensky-Martens |
+20+200:1°C |
enclosed scale |
57 mm |
||
M234000 |
flash point Marcusson |
+40+260:1°C |
enclosed scale |
48 mm |
||
M234002 |
flash point Marcusson |
+190+410:1°C |
enclosed scale |
48 mm |
||
M234550 |
-5+300:1°C |
solid stem |
76 mm |
|||
M235000 |
dropping point thermometer Ubbelohde |
0+110:1°C |
enclosed scale |
total |
||
M238040 |
|
0+55:0,2°C |
enclosed scale |
90mm |
||
M238042 |
viskosimeter Engler |
0+105:0,5°C |
enclosed scale |
90mm |
||
M240102 |
viskosimeter Vogel-Ossag |
0+35:0,1°C |
enclosed scale |
208mm |
||
M240104 |
viskosimeter Vogel-Ossag |
+35+70:0,1°C |
enclosed scale |
208mm |
||
M240106 |
viskosimeter Vogel-Ossag |
+70+105:0,1°C |
enclosed scale |
208mm |
||
M240108 |
viskosimeter Vogel-Ossag |
+90+150:0,2°C |
enclosed scale |
208mm |
||
M 241030 |
viskosimeter for the ball-draw |
-1+51:0,1°C |
enclosed scale |
140mm |
||
M241200 |
viskosimeter falling ball |
+19+21:0,02°C |
enclosed scale |
total |
||
M241202 |
viskosimeter falling ball |
-1+26:0,1°C |
enclosed scale |
total |
||
M241208 |
viskosimeter falling ball |
+74+101:0,1°C |
enclosed scale |
total |
||
M242020 |
-70+50:1°C |
enclosed scale |
180mm |
|||
M242024 |
setting point |
-38+50:1°C |
enclosed scale |
180mm |
||
M242360 |
cloud and pour point |
-38+50:1°C |
solid stem |
108mm |
||
M242362 |
cloud and pour point |
-80+20:1°C |
solid stem |
76mm |
||
M247300 |
|
0+100:0,5°C |
solid stem |
total |
||
M247350 |
congealing point paraffin |
+38+82:0,1°C |
solid stem |
79mm |
||
M253600 |
|
+4,0+6,0:0,01°C |
enclosed scale |
total |
||
M255100 |
-2+80:0,2°C |
solid stem |
total |
|||
M255102 |
softening point |
+30+200:0,5°C |
solid stem |
total |
||
M257260 |
-38+30:0,5°C |
solid stem |
250mm |
|||
D258400 |
|
0+300:1°C |
solid stem |
total |
||
D258402 |
distillation, ASTM |
0+400:1°C |
solid stem |
total |
||
D259500 |
distillation, Kraemer-Spilker |
+60+210:0,2°C |
enclosed scale |
90mm |
||
D259502 |
distillation, Kraemer-Spilker |
+75+115:0,05°C |
enclosed scale |
90mm |
Metal cases, metal ferrules and accessories for before mentioned thermometers are available.
|
||
Catalogue numbers |
Viskosimeter thermometers, Ubbelohde DIN 51562 suitable for government testing or suitable for official calibration and government tested with verification certificate or offically calibrated with calibration certificate; enclosed scale, Hg filling, capillary colourless, total immersion. |
|
Catalogue numbers |
Thermostat control thermometers, suitable for government testing, enclosed scale, various measuring ranges in 0,1°C or 0,2°C, Hg filling, capillary colourless, immersion 140mm. |
|
Catalogue numbers |
Melting point thermometers,suitable for government testing, enclosed scale, measuring ranges from -38 upto +360°C, Hg filling, immersion 30mm and 50mm (Lindström). |